Notice 313955438 served against Charles Watts Engineering Limited on 10/01/2024 | |||
---|---|---|---|
Notice Type | Improvement Notice | ||
Description | IN issued as you do not have effective arrangements for the monitoring and review of the preventative and protective measures, e.g. interlocks and guards, to prevent access to the dangerous parts on your machinery IN issued as you have failed to ensure that your employees’ exposure to water-mix metal working fluids, a substance hazardous to health and asthmagen, is either prevented or, where not reasonably practicable, adequately controlled, because you have not installed local exhaust ventilation on each of your CNC machines using such substances. IN issued as you have failed to provide appropriate health surveillance for your employees who, in the course of their work activities, are being exposed to welding fume and water-mix metal working fluids, which are a substances hazardous to health. | ||
Compliance Date | 20/02/2024 | Revised Compliance Date | |
Result | Complied with | ||
Location of Offence | |||||
---|---|---|---|---|---|
Address | Rugby/Charles Watts Engineerin Charles Watts Engineering Ltd 94 Somers Road RUGBY Warwickshire CV22 7DH England |
Region | Midlands | ||
Local Authority | Rugby | ||||
Industry | Manufacturing | ||||
Main Activity | 25110 - MF METAL (PARTIAL) STRUCTURES | ||||
Type of Location | Fixed | ||||
HSE Details | |||||
HSE Group | ISDIIU4G19 | HSE Directorate | INSPECTION DIVISION | ||
HSE Area | HSE Division | West Midlands |