Notices served
Notice 313102237 served against Kenbury Wood Limited on 11/01/2023 | |||
---|---|---|---|
Notice Type | Improvement Notice | ||
Description | IN1/ you have failed to implement a suitably robust safe system of work for operation and maintenance of the trommel , in order to ensure that, so far as is reasonably practicable, operations which involve a risk to safety, including clearing blockages and maintenance activities, are carried out while the plant is shut down, and that re-connection of any energy sources to the trommel does not expose any person to any risk to safety IN2/ You have failed to put arrangements in place to ensure that machinery guarding provided to prevent access to dangerous parts on machinery is maintained in an efficiant state as originally designed and installed IN3/ you have not ensured that all fixed and portable access equipment (ladders) available for use at the above premesis are controlled, maintained in an efficient state, in efficient working order and in good repair | ||
Compliance Date | 03/02/2023 | Revised Compliance Date | |
Result | Complied with | ||
Location of Offence | |||||
---|---|---|---|---|---|
Address | Mulberry Court/Kenbury Wood Lt Unit 1&2, Mulberry Court Lustleigh Close, Matford Busin EXETER EX2 8PW England |
Region | Wales & South West | ||
Local Authority | Exeter | ||||
Industry | Extractive and utility supply industries | ||||
Main Activity | 38320 - RECOVERY OF SORTED MATERIALS | ||||
Type of Location | Fixed | ||||
HSE Details | |||||
HSE Group | FODOP9GP37 | HSE Directorate | Field Operations Division | ||
HSE Area | HSE Division | South West |