Notices served
| Notice 312825312 served against Helston Fabrications Limited on 13/09/2022 | |||
|---|---|---|---|
| Notice Type | Improvement Notice | ||
| Description | PN 312825274 served - the Asquith Radial Arm drill did not have a telescopic trip safety device fitted to stop the drill in an emergency IN 312825312 served - the George Cohen sons & Co guillotine was not guarded at the rear by means of a fixed gate therefore employees ae currently able to access the danger zone to the right side of the machine | ||
| Compliance Date | 04/10/2022 | Revised Compliance Date | |
| Result | Complied with | ||
| Location of Offence | |||||
|---|---|---|---|---|---|
| Address | Water-Ma-Trout/Helston Fabrica 1 Water-Ma-Trout Industrial Es HELSTON Cornwall TR13 0LW England |
Region | Wales & South West | ||
| Local Authority | Cornwall UA | ||||
| Industry | Manufacturing | ||||
| Main Activity | 25990 - MF FABRICATED METAL PROD NEC | ||||
| Type of Location | Fixed | ||||
| HSE Details | |||||
| HSE Group | FODOP9GP37 | HSE Directorate | Field Operations Division | ||
| HSE Area | HSE Division | South West | |||