This website uses non-intrusive cookies to improve your user experience. You can visit our cookie privacy page for more information.

Notices served

Notice 312526524 served against RTR Precision Engineering Limited on 20/05/2022
Notice Type Improvement Notice
Description IN/SG/12/200522/01 - 312526524. You have failed to ensure, so far as is reasonably practicable, the health of your employees at work, because you have failed to adequately control their exposure to a substance hazardous to health, namely airborne water-mix metal working fluid mist generated by your CNC machines, because you have not provided local exhaust ventiltion to control the mist at source.
Compliance Date 25/07/2022 Revised Compliance Date 22/08/2022
Result Complied with

Breaches involved in this Notice

Location of Offence
Address Collingwood Court/RTR Precisio
RTR Precision Engineering Limi
10 Collingwood Court
Riverside Park Industrial Esta
MIDDLESBROUGH
Cleveland
TS2 1RP
England
Region Yorks & North East
Local Authority Middlesbrough UA
Industry Total service industries
Main Activity 71129 - ENGINEERING ACTIVITIES NEC
Type of Location Fixed
HSE Details
HSE Group FODOP3GP12 HSE Directorate Field Operations Division
HSE Area HSE Division North East
Updated: 2020-03-04