Notices served
Notice 311908905 served against JMR Section Benders Ltd on 14/09/2021 | |||
---|---|---|---|
Notice Type | Improvement Notice | ||
Description | You have failed to prevent access to dangerous parts of machinery namely the rotating pivot head saw blade by using correct guarding such as retractable linked action guard. You have failed to make and give effect to such arrangements as are appropriate, having regard to the nature of your activities and the size of your undertaking, for the effective planning, organisation, control, monitoring, and review of the preventive and protective measures for the management of metal working fluid quality. | ||
Compliance Date | 15/10/2021 | Revised Compliance Date | |
Result | Complied with | ||
Location of Offence | |||||
---|---|---|---|---|---|
Address | Unit 8 Sterling Industrial Est Unit 8 Sterling Industrial Est Rainham Road South DAGENHAM RM10 8TX England |
Region | London | ||
Local Authority | Barking & Dagenham | ||||
Industry | Manufacturing | ||||
Main Activity | 25990 - MF FABRICATED METAL PROD NEC | ||||
Type of Location | Fixed | ||||
HSE Details | |||||
HSE Group | FODOP4GP15 | HSE Directorate | Field Operations Division | ||
HSE Area | HSE Division | London |