This website uses non-intrusive cookies to improve your user experience. You can visit our cookie privacy page for more information.

Notices served

Notice 311721812 served against Dales Engineering Services Ltd on 08/07/2021
Notice Type Improvement Notice
Description INSJD220621.1 - 311700793 You have failed to make and give effect to appropriate arrangements for the monitoring and maintenance of your water-mix metal working fluid - in that you do not (a) undertake weekly testing of the metal working fluid by appropriate tests i.e. concentration and dipslide testing for bacteria; and you do not (b) have effective procedures for remedial actions on the basis of the test results. INSJD220621.2-311700793 You have failed to ensure that the exposure of your employees to metal working fluids (MWF) is adequately controlled in that your employees in the workshop are using compressed air to blow-down and clean work-pieces after machining. PSJD220621.1-311713932 Persons are liable to come into contact with dangerous parts of machinery namely rotating chuck because you have failed to take effective measures to prevent access to the dangerous parts of the horizontal boring machine such a suitable guards or to stop the movement of dangerous parts before any part of a person enters the danger zone PSJD220621.2-311713970 Persons are liable to come into contact with dangerous parts of machinery, namely the rotating chuck because you have failed to take effective measures to prevent access to the dangerous parts of the horizontal boring machine such as suitable guards to stop the movement of dangerous before any part of a person enters the danger zone INSJD080721.1-311721812 You have failed to ensure that the exposure of your employees to welding fume is adequately controlled in that you have not provided Local Exhaust Ventilation where employees are carrying out regular and high intensity welding.
Compliance Date 29/10/2021 Revised Compliance Date 31/05/2022
Result Complied with

Breaches involved in this Notice

Location of Offence
Address Dales Ind Est/Dales Engineerin
Dales Ind Est
PETERHEAD
Aberdeenshire
AB42 3JF
Scotland
Region Scotland
Local Authority Aberdeenshire UA
Industry Manufacturing
Main Activity 25620 - MACHINING
Type of Location Fixed
HSE Details
HSE Group FODOP1GP1 HSE Directorate Field Operations Division
HSE Area HSE Division Scotland
Updated: 2020-03-04