This website uses non-intrusive cookies to improve your user experience. You can visit our cookie privacy page for more information.

Notices served

Notice 311101483 served against R D Buchan & Sons Limited on 11/11/2020
Notice Type Improvement Notice
Description IN.KES.1111120.001 - 311101483 You have failed to ensure that the exposure of your employees to substances hazardous to health, specifically fumes generated when undertaking high intensity welding of mild steel and stainless steel, is either prevented or, where this is not reasonably practicable, adequately controlled in that you have failed to provide local exhaust ventilation to extract harmful fumes and particles from the breathing zone of your employees.
Compliance Date 29/01/2021 Revised Compliance Date
Result Complied with

Breaches involved in this Notice

Location of Offence
Address Port Henry Pier/R D Buchan & S
R D Buchan & Sons Ltd
Port Henry Pier
Peterhead Harbour
PETERHEAD
Aberdeenshire
AB42 1ZY
Scotland
Region Scotland
Local Authority Aberdeenshire UA
Industry Manufacturing
Main Activity 33190 - REPAIR OF OTHER EQUIPMENT
Type of Location Fixed
HSE Details
HSE Group FODOP1GP1 HSE Directorate Field Operations Division
HSE Area HSE Division Scotland
Updated: 2020-03-04