This website uses non-intrusive cookies to improve your user experience. You can visit our cookie privacy page for more information.

Notices served

Notice 310992959 served against BAE Systems Global Combat Systems Munitions Limite on 08/10/2020
Notice Type Improvement Notice
Description 1 x Improvement Notice (PS08102020/1, 310992959) issued:- you have not taken appropriate measures to limit the extent of fire or explosion including measures to prevent the spreading of fires and the communication of explosions from one location to another or protect persons from the effects of fire or explosion in that additional controls had not implemented to prevent the powder drawer blowing out during an ignition on the PC53 machine. 2 x Improvement Notice (PS06102020/2, 310993390) issued:- you have not taken appropriate measures to limit the extent of fire or explosion including measures to prevent the spreading of fires and the communication of explosions from one location to another or protect persons from the effects of fire or explosion in that additional controls had not implemented to prevent the emergency relief chimneys within the filling machines from being left open after maintenance. The use of a padlock is not ALARP. You had recognised there was an issue and that an interlock system was possible as it was on Line 3 Blank filling machine but you had failed to implement this on any of the other machines. 3 x Improvement Notice (PS06102020/3, 310993405) issued:- Every operator must take all measures necessary to prevent major accidents and to limit their consequences for human health and the environment. You have not taken appropriate measures to limit the extent of fire or explosion including measures to prevent the spreading of fires and the communication of explosions from one location to another or protect persons from the effects of fire or explosion. You have identified that in operating the blank capping machine PC238 machine you require the operator to decant HT1 caps onto a mesh tray before being loaded into the machine. You identify in your safety report that there is potential for an explosion on the preparation table when the caps are on a sieve, being prepared to be dispensed by hand into the machine. The live capping machines do not have this issue and have had this process engineered out. You have chosen not to make similar arrangements with this machine.
Compliance Date 18/12/2020 Revised Compliance Date 01/11/2021
Result Complied with

Breaches involved in this Notice

Location of Offence
Address Radway Green /BAE Systems Glob
Radway Green
Radway Green
Barthomley Road
Alsager
Cheshire
CW2 5PJ
England
Region North West
Local Authority Cheshire East UA
Industry Manufacturing
Main Activity 20510 - MANUFACTURE OF EXPLOSIVES
Type of Location Fixed
HSE Details
HSE Group CEMHDU7E HSE Directorate Chemical Explo & Microbio Hazards Division
HSE Area HSE Division North West