This website uses non-intrusive cookies to improve your user experience. You can visit our cookie privacy page for more information.

Notices served

Notice 310955098 served against Argonaut Marine Limited on 25/09/2020
Notice Type Improvement Notice
Description IN/KES/250920/001 - 310955098 You have failed to appoint one or more persons to assist you in undertaking the measures you need to take to comply with the requirements and prohibitions imposed upon you by or under the relevant (health and safety) statutory provisions. IN/KES/250920/002 - 310955235 You have failed to carry out an examination and test of the Electac MT800ni local exhaust ventilation in the past 14 months to ensure that it is controlling exposure to your employees, as far as reasonably practicable, to harmful substances, specifically fumes and particles generated when welding and grinding stainless steel, carbon steel and aluminium.
Compliance Date 20/11/2020 Revised Compliance Date
Result Complied with

Breaches involved in this Notice

Location of Offence
Address Unit 19, Denmore Ind Est/ Argo
Argonaut Marine
Denmore Ind Est
Aberdeen

Scotland
Region Scotland
Local Authority Aberdeen City UA
Industry Manufacturing
Main Activity 25620 - MACHINING
Type of Location Fixed
HSE Details
HSE Group FODOP1GP1 HSE Directorate Field Operations Division
HSE Area HSE Division Scotland
Updated: 2020-03-04