This website uses non-intrusive cookies to improve your user experience. You can visit our cookie privacy page for more information.

Notices served

Notice 310511770 served against Hirwaun Tubular Products Limited on 12/03/2020
Notice Type Improvement Notice
Description 5 x IN issued 280220/MG01 - IN issued for failure to prevent or adequately control exposure of employees to welding fume, a substance hazardous to health, as control measures such as local exhaust ventilation are not in place. 280220/MG02 - IN issued for failure to ensure a suitable system is in place for the effective planning, control, monitoring and review of preventative and protective measures as several machines had defective or insufficient guarding. 280220/MG03 - IN issued for lack of thorough examination and test on the powder coating booths. 280220/MG04 - IN issued for failure to carry out an assessment of risk to employees from work activity, such as use of machinery and tools, which is liable to exposure those employees to noise at or above the lower exposure action value. 280220/MG05 - IN issued for failure to carry out an assessment of risk to employees from work activity, such as the use of hand grinders, which is liable to expose employees to the risk of hand arm vibration.
Compliance Date 06/05/2020 Revised Compliance Date 30/10/2020
Result Complied with

Breaches involved in this Notice

Location of Offence
Address Hirwaun Industrial Estate/Hirw

Wales
Region Wales & South West
Local Authority Rhondda, Cynon, Taff UA
Industry Manufacturing
Main Activity 25990 - MF FABRICATED METAL PROD NEC
Type of Location Fixed
HSE Details
HSE Group FODOP8GP32 HSE Directorate Field Operations Division
HSE Area HSE Division Wales
Updated: 2020-03-04