This website uses non-intrusive cookies to improve your user experience. You can visit our cookie privacy page for more information.

Notices served

Notice 310484804 served against RIM Plastics Technology Ltd on 02/03/2020
Notice Type Immediate Prohibition Notice
Description PN - TNU - 020320 - 01 - You have failed to take suitable and sufficient measures, namely the provision of suitable guard rails and other such means to prevent a person, so far as is reasonably practicable, falling from height from the end of the gantry. PN-TNU-020320-02 - You have failed to ensure ignition sources are not present within the spray room booths as you have not prevented persons taking electrical equipment that is unsuitable into the spray rooms/booths namely mobile phones or other such devices PN-TNU-020320-03 - Failure to take effective measures to prevent access to the dangerous part of the above mentioned, mixing barrel, namely the rotating shaft. PN-TNU-020320-04 - Failure to take effective measures to prevent access to the dangerous part of the above mentioned, mixing barrel, namely the rotating shaft.

Breaches involved in this Notice

Location of Offence
Address Wollaston Way/RIM Plastics Tec
Rim Plastics
Unit
Ryder Way
Basildon
Essex
S S13
England
Region East & South East
Local Authority Basildon
Industry Manufacturing
Main Activity 22290 - MF OF OTHER PLASTIC PRODUCTS
Type of Location Fixed
HSE Details
HSE Group FODOP5GP21 HSE Directorate Field Operations Division
HSE Area HSE Division East
Updated: 2020-03-04