Notices served
Notice 310462066 served against Ensco Offshore U.K. Limited on 26/02/2020 | |||
---|---|---|---|
Notice Type | Improvement Notice | ||
Description | my investigation of the Ensco 120 offshore installation port forward crane boom collapse, which occurred on the 14th February 2020, revealed that you are unable to demonstrate that you have maintained (including calibrating and testing) the boom angle sensor and boom kickout system in an efficieni working order on the port forward, port aft, and starboard cranes on said installation; or that you calibrated the boom drum counter of the port forward crane following replacement of the boom wire rope in September 2019, and as such there is a risk that safe boom angle operating limits may be exceeded, thereby increasing the risk of damage to said cranes and a boom collapse, and ¡n failing to do so you have not taken appropriate action in response to the HSE Safety Alert Bulletin No.: ED 1-2016, issued on 17th November 2016 | ||
Compliance Date | 31/03/2020 | Revised Compliance Date | 08/06/2020 |
Result | Complied with | ||
Location of Offence | |||||
---|---|---|---|---|---|
Address | ENSCO 120/ENSCO Services Limit Ensco House, Badentoy Avenue Badentoy Park ABERDEEN AB12 4YB |
Region | |||
Local Authority | Not Applicable | ||||
Industry | Extractive and utility supply industries | ||||
Main Activity | 09100 - OIL/ GAS EXTRACTION SUPPORT | ||||
Type of Location | Offshore Safety Directive Regulator | ||||
HSE Details | |||||
HSE Group | EDU1S3 | HSE Directorate | Energy Division | ||
HSE Area | HSE Division |