Notices served
Notice 309982955 served against Greif UK Limited on 17/07/2019 | |||
---|---|---|---|
Notice Type | Improvement Notice | ||
Description | IN/CSL/160719/Greif/1 - Improvement Notice - Effective measures have not been taken to prevent access to the dangerous moving parts of your "10t Cut-To-Length Machine" situated in the de-coil area because there was access into the danger zone whilst the machine was in operation, via unlocked gates. Operatives may therefore make contact with the dangerous moving parts whilst the machine is in operation. The associated risk is serious personal injury from entanglement. IN/CSL/160719/Greif/2 - Improvement Notice - Effective measures have not been taken to prevent access to the dangerous moving parts of your "Cut-To-Length Machine" situated in the de-coil area because there was whole body access into the danger zone whilst the machine was in operation, via a gap in the enclosure fencing. Operatives may therefore make contact with the dangerous moving parts whilst the machine is in operation. The associated risk is serious personal injury from entanglement. | ||
Compliance Date | 12/08/2019 | Revised Compliance Date | |
Result | Complied with | ||
Location of Offence | |||||
---|---|---|---|---|---|
Address | Merseyside Works/Greif UK Limi Merseyside Works Oil Site Rd ELLESMERE PORT CH65 4EZ England |
Region | North West | ||
Local Authority | Cheshire West and Chester UA | ||||
Industry | Manufacturing | ||||
Main Activity | 25910 - MF STEEL DRUMS/CONTAINERS | ||||
Type of Location | Fixed | ||||
HSE Details | |||||
HSE Group | FODOP2GP6 | HSE Directorate | Field Operations Division | ||
HSE Area | HSE Division | North West |