Notice 309746821 served against Firber Engineering Ltd on 05/04/2019
Notice Type Improvement Notice
Description IN served - that the compressor and associated pressure system being used on site (serial number V11-001995-1609) does not have a written scheme of examination for the periodic inspection, by a competent person, of the protective devices and those parts of the pressure vessel and pipe work, in which a defect may give rise to danger. IN served - There is no health surveillance system in place for employees that are exposed to substances that are hazardous to health including welding fume, solvent based paints and water based metal working fluids. IN served - that there is no LEV extraction system in place to control employee’s exposure to welding fume, a substance that is hazardous to health.
Compliance Date 17/05/2019 Revised Compliance Date 12/07/2019
Result Complied with

Breaches involved in this Notice

Location of Offence
Address Shelley Close/Firber Engineeri
Firber Engineering Ltd
Shelley Close
Lowmoor Business Park
NOTTINGHAM
NG17 7ET
England
Region Midlands
Local Authority Ashfield
Industry Manufacturing
Main Activity 25110 - MF METAL (PARTIAL) STRUCTURES
Type of Location Fixed
HSE Details
HSE Group FODOP7GP31 HSE Directorate Field Operations Division
HSE Area HSE Division East Midlands