Details for Case No.4814974
| Details for Case No. 4814974 | |||
|---|---|---|---|
| Defendant | Winbro Group Technologies Limited | ||
| Description | Winbro Group Technologies Limited (t/a Winbro) failed to properly plan and assess the risks from a machine lifting operation, failed to identify and implement suitable control and/or mitigation measures to ensure worker safety whilst fitting and removing machine levelling feet and failed to avoid work underneath a suspended load and/or otherwise failed to ensure the activity was carried out in a safe manner. | ||
| Offence Date | 17/01/2024 | ||
| Total Fine | £170,000.00 | Total Costs Awarded to HSE | £7,999.10 |
|
Breach involved in this Case |
|||
| Location of Offence | |||
| Address | Gelders Hall/Winbro Group Tech Winbro Group Technologies Unit 1 Illuma House, LOUGHBOROUGH Leicestershire LE12 9NH England |
Region | Midlands |
| Local Authority | Charnwood | ||
| Industry | Manufacturing | ||
| Main Activity | 28990 - MF SPECIAL-PURPOSE M/C NEC | ||
| Type of Location | Fixed | ||
| HSE Details | |||
| HSE Group | IVDIIU3G12 | HSE Directorate | INVESTIGATION DIVISION |
| HSE Area | HSE Division | East Midlands | |